Answers:With my restricted practical experience of central heating, it seems like you've far more than one particular dilemma and I suggest you receive an expert to locate the faults.
However, if a radiator isn't going to warmth up, there might be air trapped from the program (especially seeing that you've two new radiators). Air is a fantastic insulator and may cease a radiator from gaining very hot. attempt to bleed the air out. get the radiator critical (it's like a little bit metal T-piece) and open the valve with the prime in the radiator rather somewhat. The valve is like a little bit square nut. I advise you set a cloth underneath the valve to catch the h2o that can escape.
If there exists air from the program then you certainly will listen to it escaping (and you might also scent it)! shut the valve shut when no air is escaping and it is just h2o. even so, as some h2o escapes, the program strain will fall and that means you will will need to raise the strain yet again by permitting mains h2o to arrive in. (There is yet another valve for that - commonly in or about your boiler). It could be the strain from the program that can push the air out. The typical running program strain varies however it is normally among one and one.5 bar gauge strain for domestic heating techniques (when cold).
You should shut the radiator valve ahead of you allow mains h2o to the program! as soon as the strain is up at one - one.5 yet again then you certainly can return to bleeding air. (I'm not swearing at you, honest).
Gauge strain just signifies the range indicated about the strain gauge. A gauge strain of 0 is equal to one bar atmospheric strain (in other words in the event the gauge is looking at 0 then the strain inside of the heating program is equal on the air strain from the place and there can be a hole somewhere)!
Another fantastic cause why air from the program is poor is the fact that air (like any gas) is often compressed whereas h2o are unable to. So escalating the strain from the program would just compress the trapped air which can be hopeless.
So, preserve bleeding the air and escalating the strain back again as much as one bar (or what ever it ought to be - have a very start looking at your user's manual) until eventually every one of the air is gone. Hopefully then all of your radiators will warmth up! If not then you certainly in all probability have a very far more critical fault.
As for the boiler manage panel, that seems like an electrical/electronic fault and there is not considerably you may do about that by yourself.
I hope this is certainly of some aid and that your issues are only because of to trapped air!
Best wishes, F.
Answers:It seems you've far more than one particular dilemma. one. Have you bled downstairs rads. two. are you currently guaranteed the piping may be the right way set in on the residing place as this is certainly a brand new circuit that is just not functioning..3. Are every one of the valves on every stop of rads absolutely open. four. attempt turning off rads upstairs to find out if pump will then circulate the h2o. five. be sure pump is operating, warmth can head over to upstairs rads as warmth rises.
6. once you say increase, do you imply extend heating time. seven. rather usually the rad in bathroom is about the very hot h2o program and never the rad program. eight. i might phone back again the individuals who prolonged you program they must have left it all operating for your satisfaction.