Showing posts with label WIRES. Show all posts
Showing posts with label WIRES. Show all posts

Thursday, April 7, 2011

How a lot of 14 gauge wires in six cubic in pancake box.?

Qusetions: i'm hoping to substitute and aged bathroom lights fixture which can be connected to a medication cabinet. it really is an individual piece as well as the total unit may be eliminated. The medication cabinet will probably be replaced by an everyday mirror and I need to set up a whole new light fixture and middle it previously mentioned the mirror. There is actually a stud exactly where the mirror need to be centered. you will find drinking water pipes working along both facet of your stud. i used to be advised to implement a pancake junction box but my new fixture has four black, four white plus a ground wire. i am confident it could be considered a code violation to attempt to shove all people wires in to the pancake. The pancake is 4". What may be the optimum quantity of 14 gauge wires that could go in to the pancake? i'll also be working with a mounting strap and an individual cable clamp. Is there an additional alternate? It appears to be I may well ought to seem for any distinctive fixture with less wires. thank you!

Answers:3 conductors each and every #14 is two.00cu inches #12 is two.25cu inches, Your box won't need to have to become figured for that wires off of your fixture, just the everlasting wiring the #14's or #12's for premises wiring the canopy or base of your fixture is created to accommodate the wiring through the fixture so it won't ought to be integrated inside calculation. Hope this Helps

Answers:Here's an individual created to straddle the stud. it's got far more potential than a pancake.

Answers:They seriously must stamp people boxes with all the immediate meant use, they may be make to only consider an individual piece of 14-2 grounded NM (romex) cable.

Wednesday, April 6, 2011

Answers for i've only two black wires no white or ground wires that will need to connect to a change to get a light?

Qusetions: They had been linked prior to and operating but through the demo I forgot to view how they had been connected
Please enable!!!

Answers:One black may be the strength out of your panel or other supply. one other may be the strength to head to the light. the two are linked for your change.

Answers:No sweat. Your change has two screws. Attach one particular wire towards the top rated and one particular towards the bottom. not having a change, the strength would journey instantly towards the light. By setting up a change while in the center on the line you are able to interrupt the movement and prevent the strength at will. which is what you happen to be executing. The strength arrives in to the change by means of the top rated wire and when the change is "on" goes on towards the light by means of the bottom wire. if your change is "off" the strength stops in the change, as well as the light is off. ( kinda like a valve inside of a pipe ..open the valve and drinking water flows, near the valve the drinking water stops. ) The black wires are seriously one particular wire through the strength towards the lamp. placing a change while in the center controls the strength.

Answers:Both wires are or really should be (red outdated system) brown new strategy..the change is simply what it says about the tin..a change that breaks the circuit to light the light..most sparks now place a piece of brown tape to demonstrate its the reside feed about the change wires

Answers:There are meant to become two black, just place one particular in every single on the screws

Monday, April 4, 2011

Im changing the previous thermostat that goes on the wall furnace the new thermostat has 5 area for wires to?

Qusetions: my previous a single only has two wires where by do i place them the new thermostat has the letters g w r y c i place the white a single within the w then the red a single within the r it did not function the brand name is Dayton make sure you help

Answers:g is for fan
w is for heat
r is for power
y is for air conditioning
c is for that other facet with the power

When you've two stage heating or two stage cooling:

w1 is 1st stage heat
w2 is 2nd stage heat
y1 is for 1st stage cooling
y2 is for 2nd stage cooling

If your alternative thermostat isn't going to have batteries and involves energy to function, then it requires to become driven from the r and c terminals.

Just like GM rims do not match Toyota, you have to have to match the thermostat for your furnace!

Answers:The thermostat you've almost certainly is not compatible together with your furnace. Your furnace almost certainly includes a thermopile that's stored scorching from the pilot flame and generates 750mv (milivolts). maintain the two furnace wires with each other and make sure the furnace is doing work then obtain the appropriate thermostat.

Answers:I replaced mine, and then the thermostat had the identical five locations, also. I, also, only had two wires, however the instructions advised me where by to place them. there have been four unique feasible configurations. All I needed to do was figure out which i used to be to work with.

Re-read the instructions meticulously.

Thursday, March 24, 2011

I am seeking to get a very difficult wires video clip surveillance technique that I can see my residence around the net when i'm away?

Qusetions: I haven't any complications putting in any electrical technique, I just imagined i'd throw it up in to the air

Answers:http://www.ehomesurveillancecameras.com/… has some wonderful facts on deciding on a surveillance technique on your residence.

Answers:There are numerous choices around, just make certain to choose a reliable enterprise that will help you by any means instances.

How to set up a GFI with two black wires and 1 white wire?

Qusetions: i'm setting up a GFI in the kitchen application, the previous wall outlet had 1 black and 1 white wire related to your best screws around the outlet plus a 2nd black connected to your bottom screw. seeing that the GFI won't run with this particular connection how do I tie the GFI the right way to the circut? Can I pigtail the two black wires and attach them to your best conclude on the GFI

Answers:Yes, you could. nevertheless, this isn't going to make any feeling. query: start looking on the previous receptacle, the aspect with all the gold (or dark) colored screws: involving the screws, there may be suppose to become just a little tab that connects the two screws. If that tab is lacking, it is time for you to do some exploration regarding WHY it is been eliminated. great luck in all you do and may possibly God bless.

Answers:Check the back again on the box to view if a 2nd white wire has slipped out the bottom on the box. employing a multi meter or check light, examine just about every black wire with all the white to view that is carrying present-day. that is certainly your line wire. will not connect one other black to your load until eventually you locate the 2nd white wire or determine what exactly is heading on. for those who cannot establish exactly where one other black leads, cap it using a wire nut.

Answers:You will need to locate out which black wire may be the incoming scorching. This wire will get related to your (LINE) terminal. one other black wire will get related to your (LOAD) terminal. underneath this issue, any added outlets are guarded from the GFI. The white wire goes to your opposite aspect on the outlet.

Sunday, March 20, 2011

HIDING television WIRES by WALL !!!?

Qusetions: I have a very query pertaining to putting in a plasma on the brick wall. i might like conceal the cable behind the wall, the brick wall I’m putting in it on utilized to be considered a fireplace, although not any more. so it’s not brick every one of the way by since it had been a fireplace, so could I just drill a hole each ends, with the bottom and leading and set the wires by, or do I must cover the wires with a little something to defend it, assist make sure you !!!

Answers:If it truly is your home, you'll be able to do anything at all you like. nonetheless, if it truly is ever before marketed, the foreseeable future home owners might make use of the fireplace then the wire (if you depart it) will catch on fire. set the wire about the wall, not in it. check out:

http://www.acehardware.com/product/index…

or

http://cableorganizer.com/wiremold/low-v…

This would be to be utilized for low-voltage wires only.
Different wire-mold should be utilized for line-voltage techniques. Hope this aids. excellent luck in all you do and might God bless.

Answers:PEr setting up electrical codes, you are usually not permitted to run transportable cords or electrical gadget connection cords by concealed walls within a home. You must set up an accepted backbox while in the wall with completely related cables in it. Plus you require to maintain the communications cables and then the 120volt energy cables separated. You require to mount a divided junction box about the brick, or channel it out to match a single in flush. then you definitely can run cables by the area behind and tie them to the home wiring techniques. then you definitely can plug the cable connectors and energy plug to the mounted outlets. possibly most effective to phone an electrician to do that -- they must do it every one of the time now that individuals are getting significant wall-mount television's

Answers:you can do each..... if there can be a gap behind the wall to hang wires, then cool..otherwise you require to drill down some area for wires.....or else you'll be able to conceal wires which has a cover and give it a wall shade so it is going to not seem odd..... test this picture http://www.nextdaytechs.com/resources/im…
if you wish industry experts to assist you on this then phone nextday techs to set up it...check their web page....

Answers:I consider this may impact foreseeable future usability of your fireplace- just pondering resale worth. Have you deemed making use of a merchandise to corral the wired and run them inconspicuously out of your way? They offer them in your house merchants and a few are paintable, so that you could disguise that way.

Answers:sure, seems like you could possibly do this, concerning the only factor added you could possibly do is just after you ran the wires use some caulk about the wires to seal the hole and cease air from coming through